Taco room thermostat

Taco Room thermostat


I would like to use a Taco 568-14 thermostat to replace my exisiting Honeywell T87 thermostat. I have a hot water gas boiler but no Taco zone valves. Instead, I have Honeywell relays that control the booster pumps. The Taco 568-14 room thermostat is designed for control of Taco Zone valves. It is a simple thermostat with a positive snap action switch and a spiral type bi-metal element for sensitive control. It doesnt have a mercury switch like the Honywell does. Can I use this Taco thermostat in place of the honeywell T87? Thanks!! Probably. I am not familiar with the Taco thermostat but often a thermostat for a zone valve will have a SPDT switching action. There will be three wire terminals, one of which is a common. The common terminal will make (connect) to one of the two remaining terminals on a call for heat and drive the zone valve open. When the thermostat has been satisfied the common terminal will break (disconnect) from this first connection and make to the other connection and that will drive the zone valve closed. What you will need to do is determine which terminal is common and which terminal the common closes to when calling for heat. Ignore the third terminal. It will not matter which of the two wires from your thermostat cable is connected to the two identified terminals on the Taco thermostat. That stat is about the cheapest thing you can possibly buy. They are notoriously inaccurate, even worse than T87's. I suggest an inexpensive White Rogers or Honeywell digital. They don't have to be complex or programable. Honeywell makes a digital round thermostat which is a direct replacement for the T87 you have now. Every single one I've installed customers have really liked. ...even worse than T87's HEY! The T87 is the best $2.00 thermostat on the market. Too bad you can't buy one for $2.00 I agree with Grady about purchasing and installing a digital thermostat. Even a $10.00 ($20.?) LUX brand digital would be an improvement over an old bimetal thermostat.








Related Posts:




  • Tac thermostat model 31100 for normallyopen zone valve

    TAC thermostat (model 31-100) for Normally-open zone valveMy condo has a central boiler on top of the 12-storey building that feeds hot water to baseboard heater in each unit. There is a room ther...


  • Taco zone valve wiring

    Taco zone valve wiringFirst post, new to the forums. Im trying to add two Taco 571 zone valves to my baseboard hot water system. My set up is this: a Slant/fin Sentry 105K BTU gas fired furnace wi...


  • Taco sr502 and honeywell w8665e

    Taco sr502 and honeywell w8665eI'm trying to hookup a honeywell w8665e wireless thermostat receiver module to a taco sr502 relay for a heat application. I'm really unclear on how it should be wire...


  • Thermostat on water heater not working weil mclain gold plus 40

    Thermostat on Water Heater not working Weil Mclain Gold Plus 40Hi, I just moved into a house that has a Weil Mclain Gold Plus indirect water heater. I have the temperature set to the factory recom...


  • Taco zone valve problem

    Taco Zone Valve ProblemI have a 3 wire Taco zone valve and I'm not getting heat on that zone. The t stat is a new Honeywell type that looks like the old round ones but has no mercury switch in it....