Old home 3 inch dryer vent fire hazard

Old home, 3 inch dryer vent, fire hazard?


My friend just bought an old house, it has a 3 inch dryer vent that disappears into a wall and exits at the roof. We bought a 4 to 3 inch conversion and hooked up his dryer. We went on the roof and air comes out freely, is it a fire hazard? What kind of tubing is in the wall. If it is the old plastic flexible stuff replaced it. it is metal going up through the roof like a smoke stack with no cover on it You mean the 3 pipe sticks straight up to the sky? No cover? Buy a stack cover. If it is rigid steel duct, it may not be a fire hazard, but could violate local code. I personally would not want a dryer duct buried in the wall, but appears OK under IRC code. Rigid ducts is min .016 metal wall, no screws at joints. And it should be thoroughly cleaned periodically. 2006 IRC M1502.3 requires duct size per manufacturers recommendations, for most that is 4. M1502.4-transition ducts shall not be concealed within construction.... a transition duct is the flex duct from the dryer to the rigid duct. Max allowed is 8', no plastic allowed. M1502.6-max duct length is 25', Each 45deg =2.5', each 90 deg=5'. Originally Posted by Just Bill If it is rigid steel duct, it may not be a fire hazard, but could violate local code. I personally would not want a dryer duct buried in the wall, but appears OK under IRC code. Rigid ducts is min .016 metal wall, no screws at joints. And it should be thoroughly cleaned periodically. 2006 IRC M1502.3 requires duct size per manufacturers recommendations, for most that is 4. M1502.4-transition ducts shall not be concealed within construction.... a transition duct is the flex duct from the dryer to the rigid duct. Max allowed is 8', no plastic allowed. M1502.6-max duct length is 25', Each 45deg =2.5', each 90 deg=5'. wow.. great answers, thanks a lot! I am going to love this forum








Related Posts:




  • No vent on electric dryer should i be concerned

    No Vent on Electric Dryer, Should I Be Concerned?I apologize if this is a repeat question. I did a quick forum search but there were too many threads with dryer vent to go through. I rent an apart...


  • Plastic dryer duct vs metal

    plastic dryer duct vs metalI've used plastic dryer duct for 46 years and never had a problem. Now all of a sudden you hear about dryer fires all the time. Why in the world would you want to use me...


  • Mobile home hvac ductwork

    mobile home hvac ductworkI want to replace the ductwork under my mobile home. It has a single 5 by 12 rectangular duct about 60 feet long. Can I replace it with round metal or flexible ducting and...


  • Kitchenaid dryer suddenly lost heat

    KitchenAid Dryer suddenly lost heatHi, We have a KitchenAid washer/dryer combo that was purchased in 2005. The dryer doesn't get worked every day, as the wife prefers to hang out our clothes when...


  • Maytag dryer not heating up

    Maytag Dryer not heating up.Hello, we have a Maytag dryer model no.SDE305DAYW. We've had it for a couple of years no problems at all. Now it won't heat up. Everything else works just no heat. We h...